C Series 100 kVA DG Set 50Hz

  • C Series 100 kVA DG Set 50Hz Manufacturers, C Series 100 kVA DG Set 50Hz Factory, Supply C Series 100 kVA DG Set 50Hz
  • C Series 100 kVA DG Set 50Hz Manufacturers, C Series 100 kVA DG Set 50Hz Factory, Supply C Series 100 kVA DG Set 50Hz
  • C Series 100 kVA DG Set 50Hz Manufacturers, C Series 100 kVA DG Set 50Hz Factory, Supply C Series 100 kVA DG Set 50Hz
  • C Series 100 kVA DG Set 50Hz Manufacturers, C Series 100 kVA DG Set 50Hz Factory, Supply C Series 100 kVA DG Set 50Hz
C Series 100 kVA DG Set 50Hz
  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 100 kVA DG Set 50Hz is powered by Cummins diesel engine 6BT5.9-G1 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. Cummins serves customers with International Warranty Services (IWS). Matters related to diesel engine generator set operation for C Series 100 kVA DG Set 50Hz

I.Matters related to diesel engine generator set operation for C Series 100 kVA DG Set 50Hz

1. Manual test machine

Manual start of the C Series 100 kVA DG Set 50Hz: first test that the alarm system is normal, then switch the control switch to the manual (MAN) position, the generator can start by itself. Engine Generator Set manual stop: Turn the control switch to the STOP position or press the red emergency stop button to stop the generator. In an emergency, you can directly press the emergency stop button to force a shutdown. If you press the red emergency stop button, you must return to the original position, otherwise the engine genset will not start.

2. Automatic switching control

Switch the control switch to AUTO, and use it in conjunction with the automatic power switch (ATS) control switch. When the mains is stopped, A·T·S will give the start signal to the generator control system. The generator will start automatically. When the control switch is switched to STOP, or remains at automatic, but the mains has been restored, the ATS will send a stop signal and the generator will automatically stop. Note: When the generator is running automatically shut down due to a fault (over speed, high water temperature, low oil pressure, etc.), after troubleshooting, the fault reset button must be pressed down to prepare for restart.

Moreover, it related to the following configuration for C Series 100 kVA DG Set 50Hz:

C Series 100 kVA DG Set 50Hz Specification
Generator Model
BP-C100Engine Model Cummins 6BT5.9-G1 (DCEC)
Standby Power 100kVA/80kW Prime Power 90kVA/72kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 100 kVA DG Set 50Hz

Governor Mechanical Weight 432KG
No. of Cylinders 6Aspiration Turbocharged
Displacement 5.9L Fuel System

BYC A Direct

 Injection

Hourly Fuel 

Consumption 

(100% Output 

Power)

21.7L

Minimum Required 

Oil Capacity

16.4L
Power Range

 86-92kW

Horse Power Range

115-123

Cummins 6BT series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel generator sets with great transient response, wide application, high economic efficiency & high reliability, and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. As a leading manufacturer of power equipment, Cummins serves customers with International Warranty Services (IWS) in approximately 190 countries and territories through a network of more than 600 company-owned and independent distributor locations and approximately 7,400 dealer locations.

100 kVA Generator

Alternator: Stamford, Leroy Somer, Marathon, Mecc Alte, Engga, etc. With great excitation, enable genset to bear high power transient load. Ratings: Power Factor 0.8, 3 Phase 4 Wire, H insulation & IP23;

Control System: ComAp, Deepsea, Smartgen, etc. To control gensets intelligently and support genset in stable operation;

Shortcut Protection: standard three phase Delixi MCCB. Schneider & ABB for options

Radiator: standard 50℃ radiator, closed water cooled system, to support rated power output under strict temperature environment

Anti-vibration Shock Absorbers: with built-in integrated anti-vibration system, easy for transportation & installation

Fuel Tank: open type without fuel tank and silent type with built-in fuel tank (8-10 operating hours capacity);

Start Motor: DC 24V start motor;

Battery & charger: with 2 maintenance free batteries (100AH) and one DC battery charger (24V), to support genset with reliable starting power supply;

Dimension: 2250mm*950mm*1530mm (Open type); 2980*980*1585mm (Silent type)

Weight: 1200 kg (Open type); 1690 kg (Silent type)

3.From the above specification we need to check before C Series 100 kVA DG Set 50Hz operation::

① Visual inspection:

Whether the engine is damaged, missing parts, screws, generator output cables or control cables are damaged or loose.

②. Fuel system:

Whether the amount of fuel is sufficient, whether the wiring piping is leaking or the pipe fittings are loose (etc.), remove the air in the fuel system.

Lubrication system: Is the engine oil sufficient? The following maintenance must be implemented for a new engine or an engine reinstalled after an overhaul during the first 50 hours of operation: A. Engine lubricant replacement; B. Engine oil filter replacement; C. Engine diesel filter replacement; D. Valve Check and adjust the valve clearance; E. Check the external screws of the engine. To

③ Cooling system: Is the water volume for cooling the radiator sufficient? Add rust inhibitor.

④ Battery: Is the electrolyte of the battery at the normal level? Is the voltage correct? Is the connector loose? To

⑤ Does the charger work normally?

⑥ Exhaust system: Whether the muffler is damaged and whether the exhaust pipe is installed firmly.

⑦. Do not store flammable materials and sundries around the unit.

⑧. Whether the ventilation of the dg genset room is good.

4. Please pay attention to the following points during diesel home backup generator for C Series 100 kVA DG Set 50Hz operation:

① AC ammeter: the needle indicates whether it is normal, switch the current switch to measure the phase current value between each phase sequence, the phase difference between each phase sequence should not exceed 10%.

② AC Voltmeter: Whether the voltage indicated by the needle is normal.

③. Whether the oil pressure indicated by the oil pressure gauge is in the normal range.

④ Charging meter: Whether the pointer is in the (+) direction.

⑤ Whether the water temperature indicated by the water temperature gauge is within the normal range of 65℃~ 93℃.

⑥ Tachometer: Whether the number of revolutions of the engine is appropriate. (60Hz is 1800 rpm) 

⑦. Whether the genset engine has abnormal sound or vibration.

III. Introduction to common faults:

1. Why does the exhaust pipe sometimes drip oil when the C Series 100 kVA DG Set 50Hz generator load is too low?

Because there are many places in the engine that use pressure seals, such as the cylinder liner-piston-piston ring, and the turbocharger-supercharger rotor shaft, this kind of seal is generally used when the engine has about 1/3 of the load. It is effective, and slight leakage may occur when the load is small. Therefore, foreign dg set manufacturers generally give emphasis in their manuals.

If the unit is running under light load, as the running time continues, the following faults will occur:

①. The piston-cylinder liner is not well sealed, and the oil runs up and enters the combustion chamber to burn, and the exhaust emits blue smoke.

② For supercharged dg set, the supercharging pressure is low due to low load and no load. It is easy to cause the sealing effect of the turbocharger oil seal (non-contact type) to decrease, and the oil rushes into the booster chamber and enters the cylinder with the intake air.

③. Part of the oil moving up to the cylinder participates in the combustion, and part of the oil cannot be completely burned, forming carbon deposits on the valve, intake passage, piston crown, piston ring, etc., and some of it is discharged with the exhaust gas. In this way, oil will gradually accumulate in the exhaust duct of the cylinder liner, and coke will also form.

④. When oil accumulates in the pressurizing chamber of the turbocharger to a certain extent, it will leak from the joint surface of the turbocharger.

⑤ Long-term low-load operation will cause more serious wear and tear of moving parts, deterioration of the engine's combustion environment, and other consequences that lead to the advancement of the overhaul period. Therefore,foreign dg genset manufacturers emphasize whether they use naturally aspirated or supercharged models to minimize low-load/no-load operation time, and stipulate that the minimum load cannot be lower than 25%-30% of the unit's rated power.

2. Diesel engine generator stalls or runs unstable

3. The dg set cannot be started

4. Indication of engine diesel generator oil pressure is too high

5. Indication of diesel engine oil pressure is too low

6. The engine genset turbocharger leaks oil

7. Dg set exhaust smoke becomes white or blue

8. The exhaust gas concentration of prime and standby generator is too high

9. The water temperature indication of power genset is low

10. The dg set output voltage is unstable

11. The diesel generator output voltage is too high or too low

12. The working frequency of the engine generator is unstable


FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more